trichlorofluoromethane;Freon-11

GB No. 22047
CAS No. 75-69-4
Molecular Formula CCl3F
molecular weight of 137.37

2. The impact on the environment :
the substance of the environmental hazards, the body of water can cause pollution, the importance of the human food chain, especially in aquatic organisms occurred bioaccumulative. The substance of atmospheric ozone extremely damaging.


a health hazard


pathways : inhalation.
health hazards : high concentrations can induce cardiac arrhythmia and inhibition appointed respiratory function. For aerosol sprays, are found asthma cases of sudden death in the report. On the chronic effects not been reported.


two, toxicology information and environmental behavior


toxicity : low toxicity category is a weak anesthetic.
acute toxicity : LC5010pph 1 / 2 hours (mice inhaled); LC50517g/m3, 30 minutes (small / rat inhalation); Inhalation of 5%, eye irritation, dizziness.
hazardous characteristics : Unburning. Decomposition by high fever and emit toxic fluoride and chloride gas. In case of high fever, increased pressure within containers, cracking and the risk of explosion.
combustion (decomposition) products : carbon monoxide, carbon dioxide, hydrogen fluoride, hydrogen chloride.


3. Emergency Monitoring Methods :
Instrumental


4. Laboratory monitoring methods :
monitoring methods source categories
GC "urban and industrial wastewater analysis of organic compounds," such as Wang translated tenable wastewater
GC;
Chromatography / Mass Spectrometry "Solid Waste Assessment Test and Analysis Handbook" China Environmental Monitoring terminus translated solid waste
chromatography / mass spectrometry method of France and American EPA524.2
air quality : samples of activated carbon adsorption, carbon disulfide cleared, and then analyzed by gas chromatography (NIOSH)


5. Environmental standards :
former Soviet air workshop harmful substances maximum allowable concentration 1000mg/m3
olfactory threshold concentration 5.0ppm


6. Emergency treatment and disposal methods :
a leakage contingency


rapid withdrawal of staff from air leakage supremacy wind and isolation and strict restrictions on access. Cut off the fire source. Recommended emergency personnel wearing respirators-positive pressure self-sufficiency, wearing overalls general operations. As far as possible, cut off the source of leakage. A reasonable ventilation, accelerated proliferation. If possible, use immediately. Leak containers should be properly handled, repair, testing later use.
waste disposal methods : Proposed burning law. Waste and other fuel mix burning, burning to the full, to prevent the formation of phosgene. Incinerators emit hydrogen halide through scrubbers to remove.


two protective measures


respiratory protection : Most do not need special protection, high concentrations can wear contact since suction filtered gas masks (half-mask).
eye protection : Most do not need special protection, when necessary, wearing chemical protective safety glasses.
physical protection : general operating wear uniforms.
hand protection : Wear latex gloves.
other : no smoking scene work. Pay attention to personal hygiene. Enter cans, or other restrictive space of high concentration operations, someone custody.


three, and emergency measures


Inhalation : rapidly from the scene to fresh air. To keep the airway patency. If breathing is difficult, give oxygen. If breathing stop immediately mouth. Medical treatment.


fire fighting methods : This Unburning. Cut off the gas source. Cooling water containers, if possible to move containers from the scene empty Department.


Notice:Each item can have many explanations from different angels. If you want grasp the item comprehensively,please see below "more details data".
Structure:
Please see below "More Detailed Data"
More Detailed Data:
1) trichlorofluoromethane;Frenon-11;CFC-11
2) Fluoro-trichloro methane;trichlorofluoro-Methane;Freon-11;trichlorofluoro-methan;algofrene type 1;arcton 11;arcton 9;caswell no. 878;cfc 11;electro-cf 11;epa pesticide chemical code 000013;eskimon 11
3) Fluoro-trichloro methane;Fluorotrichloromethane;Trichlorofluoromethant;Fluorocarbon 11;Freon 11;Arcton 9;Methane, trichlorofluoro-
4) Freon 11
5) 1,2-dichlorotetrafluoroethane;Freon-114;CFC-114
6) l,1,2,2-tetrachloro-1,2-di-fluoroethane;Freon-112;CFC-112
7) 1,1,2-trichloro-1,2,2-trifluoroethane;Freon-113;CFC-113
8) chloropentafluoroethane;Freon-115;CFC-115
9) methyl fluoride;fluoromethane
10) methyl fluoride;fluoromethane
Notice Some description was translated by software and the data is only as a reference.
Patent:
1) Method of manufacturing group-III nitride compound semiconductor
2) Monitor, method of monitoring, polishing device, and method of manufacturing semiconductor wafer
3) Semiconductor device and fabrication method thereof
4) Adhesive for circuit connection, circuit connection method using the same, and circuit connection structure
5) Nitridation barriers for nitridated tunnel oxide for circuitry for flash memory technology and for LOCOS/stiisolation
6) Method of depositing metal film and metal deposition cluster including supercritical drying/cleaning module
7) Method for adjusting structures on semiconductor substrate
8) Conductive interconnections
9) Personalized hardware
10) Active package for integrated circuit